36
2. OPERATION
2-1.
Basic Operation
The LSG-H Series supports 7 main operating modes:
CC, CC+CV, CR, CR+CV, CV, CP, CP+CV
2-1-1. CC Mode
Description
In Constant Current Mode the load units will sink the
amount of current programmed.
Regardless of the voltage, the current will stay the same.
For more details on CC mode,
please see the appendix on page 171 (
7-5-1. CC Mode
).
Warning
If you change the mode or the range when the load is
already on, the load will be turned off automatically.
Operation
1.
Make sure the load is off.
2.
Press
Main
.
3.
Select CC mode with the
Mode
[F1] soft-key.
4.
Select the current range with the
I Range
[F2] soft-
key.
I Range:
High, Middle, Low
5.
Select the voltage range with the
V Range
[F3] soft-
key.
V Range:
High, Low
6.
Set the current level parameters using the scroll
wheel and number pad.
For Static mode, set
CC A Value
and /or
CC B Value
.
For Dynamic mode, set
Level1
and
Level2
.
The maximum and minimum current levels depend on
the selected ranges.
7.
To add CV mode to CC mode (CC+CV),
see page 42 (
2-1-6. +CV Mode
).
8.
Set the remaining basic configuration settings such as
the slew rate, and switching function settings.
See page 47 (
2-2. Basic Configuration
) for details.
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......