41
2-1-5. CP Mode
Description
In Constant Power Mode, the unit will maintain a constant
power by varying the current. For more details on CP
mode, see the appendix on page 173 (
7-5-3.CP Mode
).
Warning
If you change the mode or the range when the load is
already on, the load will be turned off automatically.
Operation
1.
Make sure the load is off.
2.
Press
Main
.
3.
Select CP mode with the
Mode
[F1]
soft-key.
4.
Select the current range with the
I Range
[F2] soft-
key.
I Range:
High, Middle, Low
5.
Select the voltage range with the
V Range
[F3] soft-
key.
V Range:
High, Low
6.
Set the power level parameters using the scroll wheel
and number pad.
For Static mode, set
CP A Value
and/or
CP B Value
.
For Dynamic mode, set
Level1
and
Level2
.
The maximum and minimum power levels depend on
the selected current range.
For static mode, the parameter that is set last
becomes the “active” setting. This will be shown in the
Operation Status Panel.
7.
To add CV mode to CP mode (CP+CV),
see page 42 (
2-1-6. +CV Mode
).
8.
Set the remaining basic configuration settings such as
the slew rate, and timer settings.
See page 47 (
2-2. Basic Configuration
) for details.
Display
Mode
CP
I Range
H 8.75A
V Range
H 800V
Function
Static
Configure
0.00
V
0.0000
A
0.00
W
CP B Value
0.00
CP A Value
0.00
LOAD
RS232
A Value
Fine
01/Oct/2017
W
W
Current range
Active
setting
Current
setting
Power
settings
+CV
OFF
Mode
Voltage
range
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......