185
7-7-9. Dynamic Mode
Model
LSG-175H
LSG-350H
LSG-1050H
Operating Mode
CC ,CR , CP
T1 & T2
0.025ms ~ 10ms / Res: 1us
10ms ~ 30s / Res: 1ms
Accuracy
± 100ppm of setting
Frequency Range (Freq./Duty)
1Hz ~20kHz
Frequency Resolution
1Hz~9.9Hz
0.1Hz
10Hz~99Hz
1Hz
100Hz~990Hz
10Hz
1kHz~20kHz
100Hz
Frequency Accuracy of Setting
(0.5% of set)
Duty Cycle of Setting (Freq./Duty)
1% ~99% , 0.1% step
The minimum time width is 10 us. Between 1kHz and 20kHz,
the maximum duty cycle is limited by the minimum time width.
Slew Rate Setting Range (CC Mode)
H Range
0.1400mA/us~
140.0mA/us
0.280mA/us~
280.0mA/us
0.840mA/us~
840.0mA/us
M Range
0.01400mA/us~
14.000mA/us
0.0280mA/us~
28.00mA/us
0.0840mA/us~
84.00mA/us
L Range
1.400uA/us~
1400.0uA/us
2.80uA/us~
2800uA/us
0.00840mA/us~
8.400mA/us
Slew Rate Setting Range (CR Mode)
H Range
0.01400mA/us~
14.000mA/us
0.0280mA/us~
28.00mA/us
0.0840mA/us~
84.00mA/us
M Range
0.001400mA/us~
1.4000mA/us
0.00280mA/us~
2.800mA/us
0.00840mA/us~
8.400mA/us
L Range
0.1400uA/us~
140.00uA/us
0.280uA/us~
280.0uA/us
0.000840mA/us~
0.8400mA/us
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......