66
2-5-4. UVP Ring Time
Description
The UVP Ring Time settings allows the UVP alarm to keep
sounding for a user-set amount of time after the UVP has
been tripped.
The alarm will continue ringing for the set amount of time
even if the voltage rises back above the UVP level~ unless
the alarm is cleared manually.
Operation
Press
Main
>
Configure
[F5] >
Protection
[F1] in order,
and set the
UVP Ring Time
.
UVP Ring Time:
OFF, 0~600s,Infinity
Alarm
When the voltage dips below the UVP level, the
UVP
indicator and message will appear on the LCD display. The
UVP buzzer will sound if UVP Ring Time is set.
Under this scenario the following outcomes are possible:
Pressing the Enter key will clear the message and the
buzzer. The UVP indicator will remain on the display until
the voltage level rises back above the UVP level.
If the UVP Ring Time is allowed to elapse, the buzzer will
stop. However the UVP indicator and message will
remain on screen until the voltage increases and the
message is cleared.
If the voltage rises back above the UVP level, the UVP
indicator will be cleared from the display, but the buzzer
will continue to sound until the UVP Ring Time has
elapsed and the message will remain until it has been
cleared.
Display
8.653
V
50.006
mA
0.4327
W
CV B Value
80.000
CV A Value
80.000
LOAD
RS232
A Value
Fine
01/Oct/2017
V
V
UVP Alarm
Please Press Enter
To Clear Alarm
UVP
UV
P indicator
Alarm message
when
UV
P is
set to Load Off
Mode
CV
I Range
L87.5mA
V Range
L 80V
Response
Fast
Configure
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......