Vacuum References
SRS-Vacuum Technology References
12. Filipelli AS. R., JVST A14(5) (1996) 2953, “Influence of envelope geometry on the
sensitivity of “nude” ionization gauges”
13. Suginuma S. et. al. , “Dependence of sensitivity coefficient of a nude type Bayard-
Alpert Gauge on the diameter of an envelope”, Vacuum 53 (1999) 177-180.
14. Charles Morrison, “Safety Hazard from gas discharge interactions with the Bayard-
alpert ionization gauge”, J. Vac. Sci. Technol. A 3(5) (1985) 2032
15. N. T. Peacock, “Measurement of x-ray currents in Bayard-Alpert type gauges”, J.
Vac. Sci. Technol. A 10(4) (1992) 2674
16. B. R. F. Kendall, “Ionization gauge errors at low pressures”, J. Vac. Sci. Technol.
A17(4) (1999) 2041
17. B. R. F. Kendall and E. Drubetsky, “Stable Cancellation of x-ray errors in B-A
gauges”, J. Vac. Sci. Technol A 16(3) (1998) 1163
18. Tilford, C. ,JVST A13(2) (1995) 485, “Comments on the stability of Bayard-Alpert
ionization Gauges”.
Note
: Great information on the long-term stability of commercial
B-A gauge sensitivities. Useful recommendations on gauge operation.
19. R. N. Peacock and N. T. Peacock, “Sensitivity variation of Bayard-Alpert Gauges
with and without closed grids from 10
-4
to 1 Pa”, J. Vac. Sci. Technol. A(8) (1990)
3341
20. Bills, D. G., JVST A12(2) (1994) 574, “Causes of nonstability and
nonreproducibility in widely used Bayard-Alpert ionization gauges”.
21. S. D. Woods and C. R. Tilford, “Long-term stability of two types of hot cathode
ionization gauges”, J. Vac. Sci. Technol. A3 (3) (1985) 542
22. P. C. Arnold et. al. “Non-stable behavior of widely used ionization gauges”, J. Vac.
Sci. Technol. A 12(2) (1994) 568
23. Tilford, C. et. al. , JVST 20 (1982) 1140, “Performance characteristics of a broad
range ionization gauge tube”.
24. K. Jousten and P. Rohl, “Instability of the spatial electron current distribution in hot
cathode ionization gauges as a source of sensitivity changes”, J. Vac. Sci. Technol. A
13(4) (1995) 2266
25. Arnold, P. C. et. al. ,JVST A12(2) (1994) 580, “Stable and reproducible Bayard-
Alpert ionization gauge”.(Note: The birth of Granville Phillip’s Stabil-Ion Gauge)
26. Siska, P. E. Rev. Sci. Instrum. 68(4) (1997) 1902, “Partial Rejuvenation of B-A
ionization gauge tubes”.
27. Cox. M. C. et. al., JVST A14(5) (1996) 2963 , “Filament Replacement for nude
Bayard Alpert Ionization gauges”.
Summary of Contents for RGA100
Page 4: ...SRS Residual Gas Analyzer iv...
Page 18: ...xviii Command List SRS Residual Gas Analyzer...
Page 46: ...2 14 Residual Gas Analysis Basics SRS Residual Gas Analyzer...
Page 66: ......
Page 78: ...4 12 Mass Filter Power supply SRS Residual Gas Analyzer...
Page 104: ......
Page 107: ...Programming the RGA Head 6 3 SRS Residual Gas Analyzer Error Byte Definitions 6 69...
Page 216: ...8 26 Quadrupole filter cleaning SRS Residual Gas Analyzer...
Page 246: ...11 2 SRS Residual Gas Analyzer...
Page 247: ......
Page 248: ......
Page 268: ...Appendix B SRS Residual Gas Analyzer 7...
Page 312: ...Appendix D SRS Residual Gas Analyzer 27...