Programming support
3.3 Activating a dialog from the NC program
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
3-9
3.3.3
Example 1: MMC instruction without acknowledgment
Selecting
N10 MMC("CYCLES,PICTURE_ON,T_SK.COM,PICTURE1,GUD4.DEF,,,A1","N")
N20 TEST_1 = 1
N25 G4 F10
N30 MMC("CYCLES,PICTURE_OFF","N")
M30
Parameters:
Dialog file (*.COM)
//C1(PICTURE1)
(R///USER VAR TEST_1/W/TEST_1///)
Text variable
[TEXT VARIABLES]
A1 =........Example 1: MMC command without
acknowledgment
([DPSOH00&FRPPDQGZLWKRXWDFNQRZOHGJPHQW
8VHUYDU7HVWB
Figure 3-2
Example 1 Without acknowledgment
Sequence of operations
The user variable TEST_1 from GUD4.DEF with header A1 is displayed for a short time. The
hold time comes from parts program block N25.