Tool management
6.6 Inch/metric setting
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
257
4.
Switchover by changing the machine data 10240.
$MN_SCALING_SYSTEM_IS_METRIC.
Then call tool management and Power ON reset in the already selected tool
management. This corresponds to point 3.
5.
Switchover by changing the machine data 10240.
$MN_SCALING_SYSTEM_IS_METRIC.
Then call tool management and machine control panel reset in the already selected tool
management.
–
Tool detail displays and list displays: As the individual values are immediately written
after input and are constantly updated in these displays, the data is immediately
displayed in the new unit.
–
Catalog/cabinet displays with affected data: As the entered data is only written in full
to the database when a softkey with a "Save function" (e.g. <OK>, <New cutting
edge>) is activated, the new unit only becomes active after this type of action.
See also