Diagnostics and service
5.6 Action log
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
155
See also
5.6.2
Structure of the log file
Overview
The file ACTION.COM is generated if the action log is activated, i.e. data logging is enabled.
The file ACTION.COM is a binary file and is always repeatedly overwritten as ring-type
buffer. The most recent results are located at the beginning of the file.
An empty binary file CRASH.COM is present. An intermediate status of the log
ACTION.COM is saved in the file CRASH.COM. Writing is initiated by setting the interface
signal DB19.DBX0.6 or write trigger using an alarm. This contents are kept up to the next
trigger.
Content of the log file
The log file comprises the following columns:
●
Date
●
Time
●
Name
●
Event ID
●
Event description
Example of a log file:
HMI version:
06.04.24.00
NCK version:
660000
Activated entries: HMI_START HMI_EXIT PLC_CRASH PLC_CRASH_ALARM
KEY_PRESSED KEY_PRESSED KEY_PRESSED KEY_RELEASED KEY_RELEASED
KEY_RELEASED ALARM ALARM_QUIT OPEN_WINDOW OPEN_WINDOW
OPEN_WINDOW CLOSE_WINDOW CLOSE_WINDOW CLOSE_WINDOW
CH_STATE_CHANGED OPMODE_CHANGED TOOL_CHANGED OVERRIDE PI_CMD
DOM_CMD WRITE_VAR WRITE_VAR WRITE_VAR FINDBL_CMD OVERSTORE
FILE_ACCESS AREA_CHANGED USER ACTIVATED DEACTIVATED SUSPEND
RESUME
--- Date
Time
User
Entry Id
Entry
===============================================================
--- 30.03.2006 13:26:04 HMI-Adv. 0 WRITE_VAR
NCK/PLC Var. wrote: /plc/datablock/byte[c19,0] = 64
--- 30.03.2006 13:26:04 <default> 0 OPEN_WINDOW
Windowstate changed: State 9, Index 15 in Application "DG"
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...