Structure of the DGOVW.INI file
[GLOBAL]
NrOfSignals=
[BMP]
100="<Bitmapname>"
101="..."
...
[SIG1]
text=
Item=
expr=
.
.
[SIG2].
...
[SIG<n>]
...
Significance of entries
NrOfSignals:
Number of additional signals. The signals are located in the [SIG<nr>] section, where <nr>
goes from 1 to NrOfSignals (continuously and with no gaps).
Text:
language-specific text in the form $T<TextNr>
where <TextNr> is a number in the language-specific DgOvw_xx.ini file (xx is the language
abbreviation).
non-language-specific text "<any text>".
"<any text>" is expressed exactly as it is written in this ini file.
The following configuration possibilities exist for the area or line index:
<CH>
for the channel number in which the axis is active.
<AX>
for axis number
<DRV>
for the drive number of the associated axis
<PLC_CH>
for a PLC-channel DB; is replaced by 20+ channel number of the channel
in which the channel is active.
<PLC_AX>
for a PLC axis DB; is replaced by 30+axis number;
e.g.: Item = /Channel/MachineAxis/impulseEnable[u<CH>, <AX>]
(Item: (see description of the OPI).
In this case the current channel would be used for <CH> and the current axis number for
<AX>. The value obtained can be evaluated by bits or as a whole number.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...