Tool management
6.7 Start-up of code carrier
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
269
Assignment of code carrier variable to a dialog variable according to the comparison result
INVSIGN
While reading: Sign for dialog variables.
While writing: Invert sign for code carrier variables.
Example:
C1=(<0 INVSIGN) , C2=(>=0)
●
Read:
A negative code carrier variable value corresponds to dialog variable C1, a positive value
to dialog variable C2; dialog variable C1 is converted to a positive value.
●
Write:
Dialog variable C1 is multiplied by (-1). If the value is less than 0, then the code carrier
variable is given the value from C1, otherwise the value from C2.
Note
Conversion specifications are only evaluated for dialog variables of data type "integer".
6.7.4
Example: Description file
Example of a description file or conversion file
The file name must be entered in ...\user\mmc.ini bei WToolIdSysKonv = wkonvert.txt.
The name of the file is, for example, wkonvert.txt:
Code carrier
variable
Length
(bytes)
Data format Dialog
variable
Comments
Item1
32
ASCII
T1
' Identifier
Item2
3
BCD
T2
' Duplo
Item3
2
BCD
T4 = (Tet1), T5 = (Tet2), T6 = (Tet3), T7 = (Tet4)
'Tool size Left, right, top, bottom
Item4
32
ASCII
T8
' Location type
Item5
1
BCD
T9
' Status
Item6
1
BCD
T3
' No. Tool noses
Item7
1
BCD
T10
' Type of tool monitoring
Item8
1
BCD
T11
' Type of tool search
' User tool data
Item9
4
BCD
A1
' Tool OEM1
Item10
4
BCD
A2
' Tool OEM2
'Cutting edge data
Block1 * Item6
Bitem1
2
BCD
C1
' Subtype, type
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...