Tool management
6.2 Settings in the configuration file
HMI Advanced (IM4)
194
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
; "Tool / magazine list" main menu, the "Tool details" softkey
; can be replaced by the new "Data management" softkey.
; The "Tool details" softkey is then stored with the same
; functions behind the "Data management" softkey.
; False="Tool details" remains active (default)
; True="Data management" is activated
ACTIVATE_EDGE_MANAGEMENT_IN_LISTS=False
; If adapter data is set in the NCK, then the
; magazine list can be displayed as either a transformed or
untransformed
; list (softkey in ETC menu). The display mode can
; be preset for the boot up of the HMI.
; False = not transformed (default)
; True = transformed
; START_MAGLIST_TRANSFORMED=False
; The "Tool management" softkey in the "Parameters" main menu
; can be used to branch to the list below.
; 0 = standard list depending on the respective NCK version /
; machine data (default)
; 1 = Magazine list
; 2 = Tool list
; 3 = Working offset list
START_LIST=0
; The inch/metric setting is considered for the code carrier
; !! NOTICE: The settings described here are only
; relevant if the MD $MN_CONVERT_SCALING_SYSTEM=1 is set
; in the NC.
; The entry for DATABASE_LENGTH_UNIT is only analyzed if
; no unit was entered in the tool database,
; i.e. once under normal circumstances.
; If it is an old NC without an inch/metric conversion
; function, or if $MN_CONVERT_SCALING_SYSTEM=0,
; then the NC operates without inch/metric conversion. Therefore
; no conversions are carried out in relation to the code carrier
either.
; 1 = No definition for inch/metric in relation to code carrier
(default).
; The setting $MN_CONVERT_SCALING_SYSTEM=1 in the NC means
; that inch/metric conversion is to be used.
; Therefore the user must determine the unit of the data
; on the code carrier or to be written to the code carrier.
; As with setting -1 this does not take place, all softkeys
; for code carrier activities are disabled.
; 0 = mm. It is assumed that the relevant data has been or is to be
; stored on the code carrier in mm.
. If "inch" is set in the NCK
; all softkeys are disabled and code carrier functions start.
; 1 = inch. It is assumed that the relevant data has been or is to
be
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...