Backing up and restoring data
4.3 Operating the service PC or the PG on the network
PCU-Basesoftware (IM8)
76
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
4.
Select "Permissions" and activate the "Change" square for all the users in the "Allow"
column so that files can be saved in this directory (e.g. the ghost image).
Procedure on the PCU 50.3
The following steps must be carried out on the PCU:
1.
Start the ServiceCenter with "Start Backup/Restore console".
2.
Maintain the pre-setting of the "Network Options" on the PCU:
IP address of PCU:
192.168.214.241
with subnet screen form 255.255.255.0
IP address of PG/PC: 192.168.214.250
with subnet screen form 255.255.255.0
1.
In the ServiceCenter, select the service task "Backup/Restore a Disk Image".
2.
Establish a network connection to the released directory, e.g. \\SIEMENS-
ABC4711\PCU_Backup.
3.
Restore the hard disk of the PCU using the ghost image.
Note
If the transfer is interrupted during the "Restore" process, no consistent system is
available on the hard disk, i.e. the "Restore" process cannot be repeated because the
PCU no longer boots up.
In this event, the "Emergency Boot System" on the USB memory store is used.
See also
How to backup and restore the hard disk (Page 67)
How to create a service system for PCU (Page 61)
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...