Network settings
1.
To connect the PCU to a programming device or PC, choose "Settings" in order to check
or reset the set IP addresses.
2.
Select "Use Windows settings", to keep the factory defaults. (This is the default here as
well.)
Figure 4-2
Network settings
3.
Select "Use the following settings", to set a new configuration:
–
With "Obtain an IP address automatically (DHCP)," you receive an automatically
assigned IP address from your DHCP server.
–
With "Use the following IP address," you enter an IP address in the range of
192.168.214.250 – 254 using subnet screen form 255.255.255.0.
4.
To activate a DNS name service, specify the server's IP address under "DNS Domain
Server" and the extension, e.g. "network.com" under "DNS Domain Suffix".
The default is ".local" if you don't enter anything else.
Note
Changes to the network settings that you make here only become effective after you reboot
the PCU.