Configuring the HMI system
2.1 Processing INI files
HMI Advanced (IM4)
36
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
On reaching a status from the list the application returns to the calling application. The
statuses can be separated by commas or specified as ranges <
from> - <to>, e.g. Recall(1,5-
7,48).
Highlight=<
Softkeyindex>
The horizontal (1 – 8) or vertical (9 – 16) softkey is displayed with a blue background when
the application is called.
ZuMat=<
status matrix>
The status matrix (e.g. dg\dg.zus) transferred is read and replaces the original status matrix.
RE_GR.INI
[HSoftkey texts]
HSK7 = "Special menu" // 20
The creation of OEM applications in HMI-Advanced is described in:
Reference: HMI programming package
See also
Transferring the actual task number of the HMI to the PLC (Page 116)
TASKCONF.INI (Page 327)
2.1.9
Supplementing service displays on a user-specific basis
Function
The DGOVW.INI file is used to define additional signals in drive diagnostics. The file must be
created explicitly in the mmc2 directory or addon, oem, user directory.
If the file is present, the signals in it are evaluated and displayed in the operator area
"Diagnostics" → "Service displays" → "Service overview". Language-specific and non-
language-specific texts can be configured in it.
Language-specific texts are located in language-specific INI files in the mmc2\language (or
addon, oem, user...) directory with the name DgOvwTxt_XX.ini.
A log file called dgovw.log is created in the user directory, in which error messages that
occur when the dgovw.ini file is compiled are output.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...