Parameterizing machine data
3.2 Parameterizing the control using machine data
HMI Advanced (IM4)
98
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
MD 28082: $MC_SYSTEM_FRAME_MASK
4
Workpiece reference points
5
Cycles
6
Transformations
Version 1 without system frame:
The MD does not exist or Bit 0 for the system frame for scratching or actual value setting is
not set.
Version 2 with system frame:
Bit 0 for the system frame for scratching and actual value setting is set in the MD.
Display machine data MD 9422: $MM_MA_PRESET_MODE defines the PRESET/basic
offset function in JOG mode.
0: No softkey
1: PRESET in the machine operating area (default setting)
2: Actual value setting
3: Actual value setting (see online help)
Note
To hide the PRESET, Set actual value, and Scratching softkeys, MD 9220:
$MM_USER_CLASS_PRESET can also be set.
Actual value setting
●
Actual value setting with system frame:
G500 active: The values are written to the system frame.
G500 not active: An error message is output.
●
Actual value setting without system frame:
G500 active (adjustable frames reset): Values are written to the first basic frame
according to the entry in display MD 9245: $MM_MA_PRESET_FRAMEIDX = Index of
basic frame
G500 not active: An error message is output.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...