Tool management
6.2 Settings in the configuration file
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
233
Coding of location status and tool status
Location statuses
Tool statuses
G Disabled location
G Disabled tool
F Free location
F Released tool
Z Reserved for tool in buffer
A Active tool
B Reserved for tool to be loaded
M Measured tool
L Left half location occupied
V Prewarning limit reached
R Right half location occupied
W Tool is being changed
O Upper half location occupied
P Fixed location coded tool
U Lower half location occupied
E Tool has been in use
l Left half location reserved
R Unloading marking
r Right half location reserved
B Loading marking
o Upper half location reserved
S Master tool
u Lower half location reserved
6.2.4
Parameterizing the display of bitmaps for tools
Parameter settings for bitmaps in the list
The display of the active tool, the programmed tool and the current location in the magazine
list can be freely parameterized, i.e. bitmaps can be inserted in the parameterizable columns
of individual lists. The bitmaps can be customized or created from scratch. The display is
activated in paramtm.ini.
The bitmaps described below are located in the "hmi_adv" directory.
Default bitmap settings
The bitmaps for the current tools are shown in red and those for the programmed tools are
shown in green.
Bitmap
Features
TNo. <> 0;
DNo./cutting edge no. <> 0
DLNo. <> 0
TNo. <> 0;
DNo./cutting edge no. = 0
DLNo. = 0
TNo. <> 0;
DNo./cutting edge no. <> 0;
DLNo. = 0
Current location
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...