Programming
2.6 Methods
Expanding the user interface
2-68
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
Parameters:
Softkey
Name of softkey: HS1 - HS8 and VS1 - VS8
RECALL
<RECALL> key
PU
Page Up
Screen up
PD
Page Down
Screen down
SL
Scroll left
Cursor left
SR
Scroll right
Cursor right
SU
Scroll up
Cursor up
SD
Scroll down
Cursor down
Example
HS1 = ("another softkey menu")
HS2=("no function")
PRESS(HS1)
LS("Menu1")
; load another softkey menu
Var2 = Var3 + Var1
END_PRESS
PRESS (HS2)
END_PRESS
PRESS(PU)
INDEX = INDEX -7
CALL("UP1")
END_PRESS
2.6.8
Example Version management with OUTPUT blocks
Overview
Additional variables can be added to existing dialogs when expanding the user interface. A
version identifier in parentheses is appended to the additional variables in the definition
following the variable name: (0 = Original, is not written), 1 = Version 1, 2 = Version 2, etc.
Example
DEF var100=(R//1)
; Original, corresponds to Version 0
DEF var101(1)=(S//"Hello")
; Expansion with effect from Version 1
When writing the OUTPUT block, you can specify which variables are written, with reference
to a particular version identifier.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...