Programming
2.3 Variables
Expanding the user interface
2-38
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
2.3.16
ENTRY variable
Description
The ENTRY variable can be used to check by what method a dialog has been called.
Programming
Syntax:
ENTRY
Description:
The ENTRY variable is a read only variable.
Return Value:
The result of the scan can be:
0 = No programming support
1 = Programming support (the dialog was called by programming
support)
2 = Programming s default setting from the previous
dialog (sub-dialog)
3 = Programming s recompilation
4 = Programming s recompilation with generated
comments, with # sign
5 = Programming s recompilation with generated
comments, without # sign
Example
IF ENTRY == 0
DLGL("The dialog was not called during programming")
ELSE
DLGL("The dialog was called during programming")
ENDIF