Configuring the HMI system
2.1 Processing INI files
HMI Advanced (IM4)
50
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
2.1.16
Activating the V.24 interface
Activating the V.24 interface
The serial V.24 interface can be activated in the DINO.INI file, section [System]. Here it is
possible to save files and assign them to the V.24/PG (COM1/COM2) interfaces.
The default setting is 0 (no interface parameterization).
[System]
; enable V24 setting by setting a non zero value
V24Settings=0
Procedure
To be able to use the V.24 data transfer with HMI-Advanced 7.5 on PCU 50.3, the following
steps are required:
1.
In the BIOS of the PCU 50.3 under "Advanced → I/O Devices Configuration", set the
"Internal COM1" to "Disabled".
2.
Insert the "PCI Interface Card (COM/LPT)" into the PCU 50.3 and install the supplied
driver.
3.
In the Windows device manager, rename the COM interfaces as COM1, COM2.
4.
In the Windows device manager, for each COM interface, under "Port Settings
→
Advanced", deactivate the "Enable CTS/RTS Auto Flow Control" option.
5.
Activate the V.24 interface in the DINO.INI configuration file.
See also
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...