Programming support
3.3 Activating a dialog from the NC program
Expanding the user interface
3-12
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
3.3.6
Example 4: Positioning of input/output field
Description
By specifying position parameters in the COM file, you can insert the comment field, or input
and output field, at any point in the display area.
Selecting
N15 MMC("CYCLES,PICTURE_ON, T_SK.COM; Screen2,GUD4.DEF,,,C1","S")
N20 TEST_3 = 5
N30 MMC("CYCLES,PICTURE_OFF","N")
N40 M30
Parameters:
The two parameters each consist of three numerical values; these specify the position and
length of the field. The values are specified in Twips, with 15 Twips roughly corresponding to
one pixel. The field height is defined as being 250 Twips.
Dialog file (*.COM)
//C2(Screen12)
(R///Var.Name/R/TEST_3/6000,2800,8000/200,3000,750
0)
/6000,2800,8000
Position of the comment field
/200,3000,7500
Position of input/output field
First value = 0 → Automatic positioning to default setting
No details
→ Positioning as on PCU 20 (default setting)
Meaning of values:
(./6000,2800,8000/....)
6000
Distance from left border
2800
Distance from upper border
8000
Field length