Programming
2.5 Softkey menus
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
2-61
If the start softkey definition is designated as a comment (semicolon (;) at beginning of line)
or the configuration file removed, the start softkey will not function.
//S(Start) ; Start
identifier
HS6=("1st screen form")
; horizontal SK 6 labeled "1st screen form"
PRESS(HS6)
; PRESS method for horizontal SK 6
LM("Screen form1")
; Load screen form1 function, where screen form
1 must be defined within the same file.
END_PRESS
; End of PRESS method
HS7=("2nd screen form")
; horizontal SK 7 labeled "2nd screen form"
PRESS(HS7)
; PRESS method for horizontal SK 7
LM("Screen form2")
; Load screen form2 function, where screen form
2 must be defined within the same file.
END_PRESS
; End of PRESS method
//END
; End identifier of entry block
Example
HS1 = ("new softkey menu")
HS2=("no function")
PRESS(HS1)
LS("Menu1")
; load new softkey menu
END_PRESS
PRESS (HS2)
; empty PRESS method
END_PRESS