Tool management
6.4 Job processing of tools
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
251
Result list type
You can select the result list type for each filter. determines which job functions are available
for each softkey.
There is one setting for each filter: n_ResultListType
Result list type, value range:
0:
Standard list (default) for unload, delete, into the cabinet, reactivate
1:
Load list for loading, reactivate
Example:
Paramtm.ini, [BatchTools]:
1_ResultListType = 0 ;0 = standard list
Filter restricted to one magazine
For each filter you can select whether it is restricted to a specific magazine. This should be
visible in the filter name.
There is one setting for each filter: n_FindLimitedToCurMagazine
Filter restricted to a specific magazine, value range:
TRUE:
hit list restricted to current magazine
FALSE:
(default) hit list is not restricted to the current magazine
Example:
Paramtm.ini, [BatchTools]:
1_FindLimitedToCurMagazine=true
;"True", "False"; can be restricted to current magazine
Positioning during Reactivate
For each filter you can select whether the job function can be selected, whether with job
function "Reactivate" the tool is to be positioned in a loading point.
There is one setting for each filter: n_ReactivatePositioningMode
Position at reactivate, value range:
0
Do not position
1
For each complete job ask the operator whether to position
2
Always position (default setting)
Example:
Paramtm.ini, [BatchTools]:
1_ReactivatePositioningMode=2 ;always
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...