Introduction
1.4 Licensing (solution line only)
HMI Advanced (IM4)
16
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Note
In NCK the need for a power ON/Reset depends on the procedure when commissioning:
•
If the option bit is first set and then the function is commissioned, then a reset is required
after commissioning.
•
However, if the function is commissioned first, a reset initiated and then the options bit is
set in the options manager, a reset must be carried out again to activate the changes.
No reset is required after writing the license key, the "License key set!" message appears in
the user response line.
References: Manual SINUMERIK 840Di sl, Chapter "Automation License Manager"
All options
All of the options selectable for this control are listed here. Furthermore, the list states
whether or not a valid and adequate license key has already been entered and how many
licenses are available.
Missing licenses
This displays the options that are already set, which are in the current license key but not yet
licensed. In HMI the options are only checked when booting. Consequently, HMI must be
rebooted in each case.