Configure hotkeys and PLC keys
4.2 Configuration
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
4-7
When the user changes to another operating area, the repeat status of the hotkey is cleared.
In the new area, the hotkey is considered not to have been pressed. It does not matter how
the user changed to the other operating area (operating area menu, etc.). In addition, each
time a function key is pressed (e.g., softkey, area switchover key, channel switchover key,
etc.), the status is reset.
Inputting data into fields in the current dialog does not interrupt the repetition sequence.
Pressing a softkey in the current dialog interrupts the repetition sequence with the softkey
that was used to call the current dialog.
Note
Multiple keypress is possible for HK1 - HK8 and for keys HK9 - HK49, which are reserved for
Siemens.
Example of multiple hotkey keypress
The first time the hotkey is pressed, the associated area is activated and a state/action may
be initiated in this area (entry 1). Pressing the hotkey again will execute the subsequent
entries for this hotkey and an area switchover will not take place. Once all the entries
configured for a hotkey have been executed, the cycle is repeated. The entries are always
executed in ascending order (from 0-9). Execution in descending order is not possible. There
must be no "event gaps" in the configuration (missing entries). A gap is treated like the end
of the chain and processing will restart at Key x.0 the next time a key is pressed.
Configuration:
[KeyConfiguration]
KEY1.0 = Task:=0, State:=10,
Action:=2
; Hotkey 1, 1st activation
KEY1.1 = State:=10, Action:=3
; Hotkey 1, 2nd activation
KEY1.2 = Action:=4
; Hotkey 1, 3rd activation
Entry in the KEYS.INI file for selecting the machine operating area:
KEY1.0 = Task:=0
; in the last screen the first
time the key is pressed
KEY1.1 = Task:=0, State:=0
; in the start screen the second
time the key is pressed
KEY1.2 = State:=0, Action:=3
; in the start screen the third
time the key is pressed and
selection of the 3rd softkey
KEY1.3 = State:=0, Action:=100
in the start screen the 4th
time the key is pressed and
selection of "Expand user
interface" function with the
configured action
≤
100 in
MACHINE.INI
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...