Tool management
6.2 Settings in the configuration file
HMI Advanced (IM4)
236
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
...
SKTLLIST=2 The tool list can only be activated with the manufacturer
password, i.e. it is blocked in normal operation.
SLTOOLCAB=2 The tool catalog and cabinet SKTOOLCAT=2 can only be
activated
with the manufacturer password, i.e. they are blocked in normal
operation.
...
Example 2:
●
The tool data is not deleted at unloading, but remain in the tool list (in NCK). The data
can be used for loading tools.
●
The function tool catalog and tool cabinet is not used.
The parameters can be assigned as follows:
...
[TMMODES]
...
DELETE_TOOL_ON_UNLOAD=0 The tool data is not deleted
on unloading.
...
[ACESSLEVEL]
...
SKTLLIST=7 The tool list can always be called.
SLTOOLCAB=2 The tool catalog and cabinet SKTOOLCAT=2 can only be
activated
with the manufacturer password and are blocked for the user.
...
Example 3:
●
The tool data is to be automatically deleted at unload in the magazine list.
●
The function tool catalog and tool cabinet is used.
The parameters can be assigned as follows:
...
[TMMODES]
...
DELETE_TOOL_ON_UNLOAD=1 The tool data is deleted
on unloading.
...
[ACESSLEVEL]
...
SKTLLIST=2 The tool list is only active with the manufacturer
password.
SLTOOLCAB=7 The tool catalog and tool cabinet
SKTOOLCAT=7 can be called (are not locked)
...
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...