Logged data
The following data are logged:
•
Alarm status change:
Alarms and PLC messages, incoming and outgoing. All
of the displayed alarms and messages can be logged.
•
Keys (only ShopMill):
For HMI-Advanced, this selection has no function.
•
Channel status:
Changing the channel status and the setting of the
override switch: NC/PLC states are logged. If this
information can be obtained in a timely manner, in many
cases these states can be used to verify the operation of
the MCP.
•
Window (state reached):
Using the softkeys and function keys to select screens
and to change the operator area
•
Writing NCK data:
All variables that are written via the input field (e.g. write
access operations to geometrical data such as tool
offsets and work offsets can be logged. A description of
the variables can be obtained via the Help function in the
Parameters operating area under Variable Views.
•
File accesses:
All domain services (e.g. load/unload program) are
logged.
•
PI services:
(Program Invocation)
All PI services (e.g. program selection, file deletion, tool
deletion) are logged. A description of the variables can
be obtained via the Help function in the Parameters
operating area under Variable Views.
With NCK version 7.4 and higher and NCU system software version 1.4 and higher, the
following applies to solution line:
•
Program state / channel:
The following data are logged for the events NC Start,
NC Stop, Reset, PLC Signal (trigger for the file
CRASH.COM):
NC Start, NC Stop and Reset Program:
•
The current main program that is selected (only
AUTO)
•
Complete information about the program levels (all
assigned program levels with the program names
including directory)
•
Actual NC block pointer (only AUTO and MDI) at all
levels
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...