Configuring the HMI system
2.3 Connecting network drives
HMI Advanced (IM4)
68
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
For the Machine area:
$MM_USER_CLASS_DIRECTORY1_M (9516)
$MM_USER_CLASS_DIRECTORY2_M (9517)
$MM_USER_CLASS_DIRECTORY3_M (9518)
$MM_USER_CLASS_DIRECTORY4_M (9519)
The display machine data for access authorizations are activated immediately, i.e., after
switchover to the respective application, while a change in directories takes effect only after
a restart.
Error messages
The configured network drives are evaluated when HMI-Advanced boots. This evaluation
does not check whether the connection actually exists. This check is made after the drive is
selected by the operator. If the configured path cannot be accessed, an error message is
issued.
See also
2.3.3
Connecting logical drives
Requirements
The "logical drives" softkey is available from access level 2 onwards (Service):
This is the reason that a machine operator cannot use this function, but instead only a
service technician. A restart of HMI-Advanced is necessary to update the assignment of the
softkeys.
With this softkey you can configure access to USB storage media on USB interfaces or PCU
and TCU and to network drives (option) in the Programs, Services, or Diagnostics operating
areas.
Function
The control can be connected to external network drives or other computers. This makes it
possible, for example, to execute part programs from other computers.
Two alternatives are available:
●
In the setting screen "Logic drives" under "Start-up" → "NC".
●
By configuring file LOGDRIVE.INI.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...