Configuring environment
6.2 Creating configuration data
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
6-7
Permissible file names
The file names are defined as follows:
Alsc.txt
Contains the language-dependent texts for the Siemens standard cycles
Almc.txt
Contains the language-dependent texts for the manufacturer cycles
Aluc.txt
Language-dependent user texts
Format of a text entry
Syntax
8xxxx 0 0 "Text"
Description
Assignment between text number and text in the file
Parameter
xxxx
5000 to 9899
Text identification number range reserved
for users. You must assign unique
numbers.
"text"
Text that appears in dialog
Parameters 2 and 3 are separated by blanks and act as control characters for alarm text
output. To ensure that the text format is identical to that of the alarm texts, these two
parameters must always be set to 0.
The following control characters may be inserted in text:
%n
Line break
%@x
Axis name of axis x (x is the axis number); HMI Embedded sl only
Show axis names (HMI Embedded sl and HMI Advanced):
NC access to corresponding machine data element containing the relevant axis
name; text assembly by means of the string functions it contains.
Examples:
85000 0 0
"Retraction plane"
85001 0 0
"Drilling depth"
85002 0 0
"Pitch"
85003 0 0
"Pocket radius"
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...