6:
Reluctance motor
10:
1LE1 induction motor (not a code number)
13:
1LG6 induction motor (not a code number)
17:
1LA7 induction motor (not a code number)
19:
1LA9 induction motor (not a code number)
100:
1LE1 induction motor
101:
1PC1 induction motor
105:
1LE5 induction motor
108:
1PH8 induction motor
600:
1FP1 synchronous reluctance motor
603:
1FP3 synchronous reluctance motor OEM
Dependency:
When selecting p0300 = 10 ... 19, parameters p0335, p0626, p0627, and p0628 of the thermal motor model are pre-
assigned as a function of p0307 and p0311.
For p0096 = 1 (Standard Drive Control) synchronous motor types cannot be selected.
CAUTION
If a motor is selected, which is not contained in the motor lists (p0300 < 100), then the motor code number must be
reset (p0301 = 0), if previously a motor was parameterized from the motor list.
NOTICE
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parameters that
are associated with this list cannot be changed (write protection). The write protection is canceled if the motor type
p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 1 for p0301 = 1xxxx). Write protection is
automatically canceled when the results of motor data identification are copied to the motor parameters.
The motor type of a catalog motor corresponds to the upper three digits of the code number or the following
assignment (if the particular motor type is listed):
Type/code number ranges
100 / 100xx, 110xx, 120xx, 130xx, 140xx, 150xx
108 / 108xx, 118xx, 128xx, 138xx, 148xx, 158xx
Note
Once the Control Unit has been switched on for the first time or if the factory settings have been defined accordingly,
the motor type is preconfigured to induction motor (p0300 = 1).
If a motor type has not been selected (p0300 = 0), then the drive commissioning routine cannot be exited.
A motor type with a value above p0300 >= 100 describes motors for which a motor parameter list exists.
p0300[0...n]
Motor type selection / Mot type sel
G120X_DP (PM330),
G120X_PN (PM330),
G120X_USS (PM330)
Access level: 2
Calculated: -
Data type: Integer16
Can be changed: C2(1, 3)
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: 6310
Min:
0
Max:
105
Factory setting:
0
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
513