Parameters
Table 6-3
Frequently used binector outputs (BO) of the converter
Parameter
Description
Factory setting
r0052[0...15] CO/BO: Status word 1
-
.00
1 signal: Ready for switching on
.01
1 signal: Ready for operation
.02
1 signal: Operation enabled
.03
1 signal: Fault active
The converter inverts signal r0052.03 if it is inter‐
connected to a digital output.
.04
0 signal: OFF2 active
.05
0 signal: OFF3 active
.06
1 signal: Switching on inhibited active
.07
1 signal: Alarm active
.08
0 signal: Deviation, setpoint/actual speed
.09
1 signal: Control request
.10
1 signal: Maximum speed (p1082) reached
.11
0 signal: I, M, P limit reached
.13
0 signal: Alarm, motor overtemperature
.14
1 signal: Motor clockwise rotation
.15
0 signal: Alarm, converter overload
r0053[0...11] CO/BO: Status word 2
-
.00
1 signal: DC braking active
.02
1 signal: Speed > minimum speed (p1080)
.06
1 signal: Speed ≥ setpoint speed (r1119)
p0730
BI: CU signal source for terminal DO 0
52.3
p0731
BI: CU signal source for terminal DO 1
52.2
p0732
BI: CU signal source for terminal DO 2
52.0
p0733
BI: CU signal source for terminal DO 3
52.7
p0734
BI: CU signal source for terminal DO 4
0
p0735
BI: CU signal source for terminal DO 5
0
Further information is provided in the parameter list.
Advanced commissioning
6.3 Drive control
SINAMICS G120X converter
194
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC