Fram
e
size
Height
Height in‐
cluding
shield
plate
Width
Depth
Additional depth
Clearance
2)
With oper‐
ator panel
With
G120
Smart Ac‐
cess
With I/O
Extension
Module
A
B
lateral
front
FSH 1696
(66.7)
-
548
(21.6)
393
(15.5)
-
-
-
200
(7.9)
250
(9.8)
30 (1.2) 100
(3.9)
FSJ
1621
(63.8)
-
801
(31.5)
393
(15.5)
-
-
-
200
(7.9)
250
(9.8)
30 (1.2) 100
(3.9)
1)
Additional depth of 11.8 mm/9.8 mm is required with an operator panel/G120 Smart Access mounted onto the I/O Extension
Module.
2)
The cooling air clearances A and B refer to the converter without shield plate.
3)
For tolerance reasons, we recommend a lateral clearance of approx. 1 mm. For converters FSA ... FSC, the side-by-side
mounting (with 0 mm lateral clearance) allows a maximum surrounding air temperature during operation of 50 °C; in case
of the surrounding air temperature higher than 50 °C, a lateral clearance of 50 mm or greater is required.
Drill patterns - mm (in)
Table 3-1
FSA … FSG
Drill pattern
Dimensions
FSA
FSB
FSC
FSD
FSE
FSF
FSG
$
%
A
55 (2.2)
80 (3.2)
118 (4.6) 170 (6.7) 230 (9.1) 270
(10.6)
265
(10.4)
B
221.5
(8.7)
265
(10.4)
283
(11.1)
430
(16.9)
509
(20.0)
680
(26.8)
970.5
(38.2)
Ø
5 (0.2)
5 (0.2)
5.5 (0.2) 6.0 (0.2) 6.5 (0.3) 8.5 (0.3) 12 (0.5)
Fixings (bolts,
washers, nuts)
4 × M4
4 × M4
4 × M5
4 × M5
4 × M6
4 × M8
4 × M10
Tightening torque
- Nm (lbf. in)
2.5
(22.1)
2.5
(22.1)
2.5
(22.1)
6 (53.1)
10 (88.5) 25
(221.3)
50
(442.5)
Note: For the converters FSD to FSG, a printed full-size drill pattern is supplied with each converter. This can be used to easily
drill the necessary mounting holes.
Mounting
3.4 Mounting the converter
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
63