Note
Modified parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here. In a long
list, index 99 contains the parameter number at which position the list continues.
This list consists solely of the following parameters:
r0990[0...99], r0991[0...99] ... r0999[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be read
from a higher-level control system (e.g. PROFIBUS master).
r0999[0...99]
List of modified parameters 10 / List chang par 10
Access level: 4
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Displays those parameters with a value other than the factory setting for this drive.
Dependency:
See also: r0990, r0991
Note
Modified parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here.
This list consists solely of the following parameters:
r0990[0...99], r0991[0...99] ... r0999[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be read
from a higher-level control system (e.g. PROFIBUS master).
p1000[0...n]
Speed setpoint selection / n_set sel
G120X_DP,
G120X_PN
Access level: 1
Calculated: -
Data type: Integer16
Can be changed: T
Scaling: -
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: -
Min:
0
Max:
200
Factory setting:
6
Description:
Sets the source for the speed setpoint.
For single-digit values, the following applies:
The value specifies the main setpoint.
For double-digit values, the following applies:
The left-hand digit specifies the supplementary setpoint, the right-hand digit the main setpoint.
Example:
Value = 26
--> The analog setpoint (2) supplies the supplementary setpoint.
--> The fieldbus (6) supplies the main setpoint.
Value:
0:
No main setpoint
1:
Motorized potentiometer
2:
Analog setpoint
3:
Fixed speed setpoint
6:
Fieldbus
7:
Analog setpoint 2
10:
Motor potenti no main setpoint
11:
Motor potenti motor potentiometer
12:
Motor potenti analog setpoint
13:
Motor potenti fixed speed setpoint
16:
Motor potenti fieldbus
17:
Motor potenti analog setpoint 2
Parameters
7.2 Parameter list
SINAMICS G120X converter
606