107
Parameter
Description
Enables access to the CLI over the VRF interface.
cli-listen-port { cli-listen-port }
Synopsis:
A 32-bit signed integer between 1 and 65535
Default:
22
The port the CLI will listen on for incoming connections over a VRF interface.
snmp-enabled
Synopsis:
{ true, false }
Default:
true
Enables SNMP access over the VRF interface.
snmp-listen-port { snmp-listen-port }
Synopsis:
A 32-bit signed integer between 1 and 65535
Default:
161
The port SNMP will listen on for incoming connections over a VRF interface.
5. Type
commit
and press
Enter
to save the changes, or type
revert
and press
Enter
to abort.
NOTE
Remote access through a VRF interface relies on Network Address Translation (NAT) rules to send
frames through the VRF interface to the intended service running in the global namespace. In the
case of SNMP, NAT rules are unaware of any listen IP address. As such, the listen IP address for
SNMP sessions must be set to
0.0.0.0
to allow the session to connect to services in the global
namespace.
6. If the VRF instance is to be used as a listen IP address for SNMP, make sure the
listen-ip
parameter for
SNMP sessions is set to
0.0.0.0
. For more information, refer to
Section 15.2.2, “Enabling and Configuring
Section 5.7
Managing Alarms
The alarm system in RUGGEDCOM ROX II notifies users when events of interest occur. The system is highly
configurable, allowing users to:
• Enable/disable most alarms, with the exception of mandatory alarms
• Configure whether or not an alarm triggers the failsafe relay and illuminates the alarm indicator LED on the
device
• Configure the severity of most alarms (i.e. emergency, alert, critical, error, etc.), with the exception of some
where the severity is fixed
Each alarm is categorized by its type (or subsystem):
Alarm Type
Description
Admin
Admin alarms are for administrative aspects of the device, such as feature-key problems.
Chassis
Chassis alarms are for physical or electrical problems, or similar events of interest. This includes irregular
voltages at the power supply or the insertion or removal of a module.
Switch
Switch alarms are for link up/down events on switch interfaces.
Eth
Eth alarms are for fe-cm and fe-em port related events, such as link up/down events.
WAN
WAN alarms are for T1/E1 and DDS interface related events, such as link up/down events.
Cellmodem
Cellular alarms are for cellular interface related events, such as link up/down events.
Summary of Contents for RUGGEDCOM ROX II
Page 2: ...RUGGEDCOM ROX II CLI User Guide ii ...
Page 4: ...RUGGEDCOM ROX II CLI User Guide iv ...
Page 39: ...RUGGEDCOM ROX II CLI User Guide Table of Contents xxxix 19 5 VLANs 752 ...
Page 40: ...Table of Contents RUGGEDCOM ROX II CLI User Guide xl ...
Page 46: ...Preface RUGGEDCOM ROX II CLI User Guide xlvi Customer Support ...
Page 170: ...Chapter 5 System Administration RUGGEDCOM ROX II CLI User Guide 124 Deleting a Scheduled Job ...
Page 256: ...Chapter 6 Security RUGGEDCOM ROX II CLI User Guide 210 Enabling Disabling a Firewall ...
Page 402: ...Chapter 11 Wireless RUGGEDCOM ROX II CLI User Guide 356 Managing Cellular Modem Profiles ...