Chapter 5
System Administration
RUGGEDCOM ROX II
CLI User Guide
108
Pre-Configured Alarms
Alarm Type
Description
Security
Security alarms are for certificate expiry events. This includes warnings 30 days before a certificate is set to
expire and when an expired certificate is installed.
Services
Service alarms are for events related to RUGGEDCOM ROX II services, such as time services, link failover,
Dynamic Domain Name Server (DNS) etc.
CONTENTS
•
Section 5.7.1, “Pre-Configured Alarms”
•
Section 5.7.2, “Viewing a List of Active Alarms”
•
Section 5.7.3, “Clearing and Acknowledging Alarms”
•
Section 5.7.4, “Configuring an Alarm”
Section 5.7.1
Pre-Configured Alarms
RUGGEDCOM ROX II is equipped with a series of pre-configured alarms designed to monitor and protect the
device.
Alarm Type
Alarm
Description
Suggested Resolution
Admin
Featurekey mismatch
The featurekey does not match the
serial numbers for the control module
and backplane hardware.
Move the featurekey to the correct
device with the matching hardware or
request an updated key from Siemens
Customer Support.
Admin
Featurekey partial mismatch
The featurekey does not match the
serial number for either the control
module or backplane hardware.
Move the featurekey to the correct
device with the matching hardware or
request an updated key from Siemens
Customer Support.
Chassis
PM1 bad supply
Input power to the power module is
outside nominal operating range.
Make sure the input power operating
range meets the device requirements.
Chassis
PM2 bad supply
Input power to the power module is
outside nominal operating range.
Make sure the input power operating
range meets the device requirements.
Chassis
PM1 MOV protection bad
The Metal Oxide Varistor (MOV)
protection component within the PM1
power module is damaged.
Contact Siemens Customer Support to
return the power module.
Chassis
PM2 MOV protection bad
The Metal Oxide Varistor (MOV)
protection component within the PM2
power module is damaged.
Contact Siemens Customer Support to
return the power module.
Chassis
Real-time clock battery low
The Real-Time Clock (RTC) battery in
the control module is depleted.
Contact Siemens Customer Support to
return the device for repair.
Chassis
LM Watchdog Failure
The specified line module has stopped
sending its heartbeat message to the
control module.
Inspect the line module to make sure
it is functioning properly.
Chassis
Fan-Controller Hardware Failure (For
MX5000RE Only)
The fan tray is damaged. One or more
fan trays may stop spinning.
Contact Siemens Customer Support to
return the fan module.
Chassis
Fan-Controller Overtemp (For
MX5000RE Only)
The ambient temperature within the
RuggedEnclosure has exceeded the
Power down the device until the
ambient temperature has cooled.
Summary of Contents for RUGGEDCOM ROX II
Page 2: ...RUGGEDCOM ROX II CLI User Guide ii ...
Page 4: ...RUGGEDCOM ROX II CLI User Guide iv ...
Page 39: ...RUGGEDCOM ROX II CLI User Guide Table of Contents xxxix 19 5 VLANs 752 ...
Page 40: ...Table of Contents RUGGEDCOM ROX II CLI User Guide xl ...
Page 46: ...Preface RUGGEDCOM ROX II CLI User Guide xlvi Customer Support ...
Page 170: ...Chapter 5 System Administration RUGGEDCOM ROX II CLI User Guide 124 Deleting a Scheduled Job ...
Page 256: ...Chapter 6 Security RUGGEDCOM ROX II CLI User Guide 210 Enabling Disabling a Firewall ...
Page 402: ...Chapter 11 Wireless RUGGEDCOM ROX II CLI User Guide 356 Managing Cellular Modem Profiles ...