18
– 39
PSEL
[Function]
The status of the program No. selection input signal set with the mode setting
is judged, and the tag No. is jumped to according to the input state. (Refer to
section 10.2.9.)
[Explanation]
The program No. input signal is judged at the point the PSEL command is
executed.
[Key operation]
STEP 1
Press
F 1
, and then press
IN
1
and
RET
0
. NOP changes to PSEL.
Press
ENT
.
Refer to section 13.2.5 for details on the bit No. selection input bit designation.
During multitasking, if the PSEL command is input for multiple tasks and is executed,
the "NO TAG FOUND" error will occur. Jumping to a tag No. in another task is also not
possible.
[
P
R
G
M
]
0
0
0
1
N
O
P
[
P
R
G
M
]
0
0
0
1
P
S
E
L
Program Selection
Program start
Program end
Program end
The input status of the program No.
selection signal is judged, and the
designated tag No. is jumped to.
Program selection
PSEL
command
TAG command
END command
Tag No. = 8 setting
Tag No. = 1 setting
Program 8 start
Program 8 start
Summary of Contents for CA20-M10
Page 2: ......
Page 14: ...XII 21 6 Spare parts 21 5 21 6 1 Controller spare parts 21 5 21 6 2 Axis spare parts 21 5...
Page 24: ...1 10 This page is blank...
Page 104: ...4 20 This page is blank...
Page 112: ...5 8 This page is blank...
Page 152: ...7 20 This page is blank...
Page 190: ...10 20 This page is blank...
Page 234: ...11 44 This page is blank...
Page 244: ...12 10 This page is blank...
Page 286: ...15 4 This page is blank...
Page 300: ...17 12 This page is blank...
Page 352: ...18 52 This page is blank...
Page 382: ...21 6 This page is blank...
Page 383: ......
Page 384: ...Back cover Q3178E 03 APR 20...