18
– 5
BRAC
[Function]
The command BRAC is used to jump to a program to the tag No. which is the
resultant value of a counter No. plus the set counter value.
[Key operation]
STEP 1
Press
F 1
followed by
OUT
2
and
RET
0
.
NOP changes to BRAC.
Press
ENT
.
STEP 2
Enter the counter No. with the numeric keypad.
Press
ENT
. (Input range: 1 to 99)
STEP 3
Enter the counter setting value with the numeric
key-pad. Press
ENT
. (Input range: 0 to 999)
NOTE
The control jumps to the tag No. which is the resultant value of the counter value +
counter Nos. The counter content will remain unchanged after the execution of this
command.
When the counter value details are "0" and the number to be added is "0", if the
command is executed, the "TAG NOT FOUND" error will occur.
If any total of (counter value) + (setting value) exceeds "999", "TAG NO. error" will
occur.
[
P
R
G
M
]
0
0
0
1
N
O
P
[
P
R
G
M
]
0
0
0
1
B
R
A
C [
0
1
]
+
0
0
0
Counter jump
Summary of Contents for CA20-M10
Page 2: ......
Page 14: ...XII 21 6 Spare parts 21 5 21 6 1 Controller spare parts 21 5 21 6 2 Axis spare parts 21 5...
Page 24: ...1 10 This page is blank...
Page 104: ...4 20 This page is blank...
Page 112: ...5 8 This page is blank...
Page 152: ...7 20 This page is blank...
Page 190: ...10 20 This page is blank...
Page 234: ...11 44 This page is blank...
Page 244: ...12 10 This page is blank...
Page 286: ...15 4 This page is blank...
Page 300: ...17 12 This page is blank...
Page 352: ...18 52 This page is blank...
Page 382: ...21 6 This page is blank...
Page 383: ......
Page 384: ...Back cover Q3178E 03 APR 20...