4
– 17
STEP 5
When
the
program
END
command
is
completed, the program will return to step No.
0001, program step 1 will display, and the
operation will stop.
Operation with external signals
Use the following procedure to carry out operation with the external signals. Refer to
section 17.1 on how to disconnect the Teach Pendant.
[Operation procedures]
1. Carry out return to origin with the system input return to origin. (There are cases
where Return to Origin does not need to be carried out. Refer to section 3.1.3 Return
to Origin.)
2. Input the start signal to execute the program from step 0001. If there are multiple
tasks in the multitasking, the execution will start with step 0001 of the main task.
3. If the stop signal is input during operation, the program will stop after ending the
program step currently being executed.
4. To restart from the step where the program was stopped, input the start signal.
5. To start from step 1, input the reset signal and then input the start signal. If the restart
function is valid, the reset input will be ignored. Refer to section 10.2.6 for details.
(2) Single operation
During single operation, the program will stop once after the axis movement or output
related operation is executed. To start or restart the program, input the start signal or
press
START
. Normally this is used to verify a program.
An example of single operation is given below.
1. Turn the single operation input signal ON.
2. The following operations are basically the same as continuous operation. (Refer to
section 4.2.1 (1) Continuous operation.)
3. When the program has stopped operation, press
START
or input the start signal to
sequentially start the program.
The single operation mode input bit setting in the mode setting must be set. (Refer to
section 13.2.1.)
Operation with either the Teach Pendant or external signal is possible.
The single operation input signal must retain the ON state during single operation.
If the single operation input signal is turned OFF during single operation, the remaining
program will be continuously operated.
Even if the single operation input signal is input during continuous operation, it will be
ignored, and continuous operation will continue.
The following commands can be used for stopping after execution.
MOVP, MVB, MVE, HOME, MVM
OUT, OUTP, OUTC
Summary of Contents for CA20-M10
Page 2: ......
Page 14: ...XII 21 6 Spare parts 21 5 21 6 1 Controller spare parts 21 5 21 6 2 Axis spare parts 21 5...
Page 24: ...1 10 This page is blank...
Page 104: ...4 20 This page is blank...
Page 112: ...5 8 This page is blank...
Page 152: ...7 20 This page is blank...
Page 190: ...10 20 This page is blank...
Page 234: ...11 44 This page is blank...
Page 244: ...12 10 This page is blank...
Page 286: ...15 4 This page is blank...
Page 300: ...17 12 This page is blank...
Page 352: ...18 52 This page is blank...
Page 382: ...21 6 This page is blank...
Page 383: ......
Page 384: ...Back cover Q3178E 03 APR 20...