List of Commands/Annex C
CTS55
1094.0006.55 C.18
E-8
1.5
Measurement, Analysis and Result Query
1.5.1
BER
1.5.1.1 Tolerances for the BER
Value for class-Ib Rate
Syntax:
CONFigure:LIMit:BER:CLIB:RATE
Value range:
0.0 ... 100.0
Default:
0.4
State:
ALL
Option:
none With Query
Value for class-II Rate
Syntax:
CONFigure:LIMit:BER:CLII:RATE
Value range:
0.0 ... 100.0
Default:
2.6
State:
ALL
Option:
none With Query
Values for erased frames Rate
Syntax:
CONFigure:LIMit:BER:EFRames:RATE
Value range:
0.0 ... 100.0
Default:
1.0
State:
ALL
Option:
none With Query
Number of frames to be sent
Syntax:
CONFigure:BER:FRAMestosend <numeric_value>
Value range:
1 ... 499
Default:
100
State:
ALL
Option:
none With Query