List of Error Messages/Annex B
CTS55
1094.0006.55
B.2
E-3
Contiuation: Command Error
Error code
Error text in the case of queue poll
Error explanation
-109
Missing parameter
The command contains too few parameters.
Example: The command
CONFigure:RFGen:FREQuency
requires a frequency indication.
-111
Header separator error
The header contains an impermissible separator.
Example: the header is not followed by a "White Space", "
*ESE255
"
-112
Program mnemonic too long
The header contains more than 12 characters.
-113
Undefined header
The header is not defined for the instrument.
Example:
*XYZ
is undefined for every instrument.
-114
Header suffix out of range
The header contains an impermissible numeric suffix.
Example:
SOURce3
does not exist in the instrument.
-120
Numeric data error
The command contains a faulty numeric parameter.
-121
Invalid character in number
A number contains an invalid character.
Example: An "A" in a decimal number or a "9" in an octal number.
-123
Exponent too large
The absolute value of the exponent is greater than 32000.
-124
Too many digits
The number includes too many digits.
-128
Numeric data not allowed
The command includes a number which is not allowed at this position.
Example: The command
SOURce:RFGen:SELect
requires indication of a text parameter.
-131
Invalid suffix
The suffix is invalid for this instrument.
Example: nHz is not defined.
-134
Suffix too long
The suffix contains more than 12 characters.
-138
Suffix not allowed
A suffix is not allowed for this command or at this position of the command.
Example: The command
*RCL
does not permit a suffix to be indicated.
-141
Invalid character data
The text parameter either contains an invalid character or it is invalid for this command.
Example: write error with parameter indication;
SOURce:RFGen:SELect STT1.
-144
Character data too long
The text parameter contains more than 12 characters.
-148
Character data not allowed
The text parameter is not allowed for this command or at this position of the command.
Example: The command
*RCL
requires a number to be indicated.
Summary of Contents for 1094.0006.50
Page 4: ......
Page 12: ......
Page 22: ......
Page 24: ......
Page 26: ......
Page 28: ......
Page 30: ......
Page 41: ...CTS55 Getting Started With Autotest 1094 0006 55 3 3 E 7...
Page 66: ......
Page 81: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 7 E 6...
Page 83: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 9 E 6...
Page 106: ......
Page 108: ......
Page 196: ......
Page 246: ......
Page 250: ......
Page 254: ......
Page 256: ......
Page 343: ...CTS K6 Windows Application CTSgo 1079 2001 01 87 E 3 Fig CTSgo help window...