Remote Control
CTS55
1094.0006.55
11.24
E-5
Example 2: Set RF generator in Module Test
Send the following commands to the CTS via a terminal program
Command
Comment
proc:sel modidle
go to state "MODIDLE"
proc:sel iqspec
select IQ Spectrum
proc:sel rfg
select rf generator
conf:rfg:freq 950 MHz
set rfg to 950 MHz
conf:rfg:pow -60 dBm
set rf level at RFINOUT
conf:rfg:lev on
and switch it on
conf:rfg:freq:off 67 kHz
set frequency offset
conf:rfg:dm:form 0
set midamble (training sequence) = 0
conf:rfg:dm:mode dummy
modulation = dummy bursts
conf:rfg:ramp:stat on
set ramping = on
Use a spectrum analyzer to check the output signal at connector RFINOUT.
(center = 950 MHz, span = 1 MHz, Reflev = -60 dBm)
Summary of Contents for 1094.0006.50
Page 4: ......
Page 12: ......
Page 22: ......
Page 24: ......
Page 26: ......
Page 28: ......
Page 30: ......
Page 41: ...CTS55 Getting Started With Autotest 1094 0006 55 3 3 E 7...
Page 66: ......
Page 81: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 7 E 6...
Page 83: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 9 E 6...
Page 106: ......
Page 108: ......
Page 196: ......
Page 246: ......
Page 250: ......
Page 254: ......
Page 256: ......
Page 343: ...CTS K6 Windows Application CTSgo 1079 2001 01 87 E 3 Fig CTSgo help window...