CTS55
List of Commands/Annex C
1094.0006.55 C.7
E-8
Dialled number
Syntax:
SENSe:SIGNalling:DNUMber?
Return:
<string>
(max. 20 digits) or “- - -“
State:
MCE
Option:
none Query only
Note:
(N2)
Power Class
Syntax:
SENSe:SIGNalling:POWer:CLASs?
Return:
GSM:
1
...
5
GSM850
1 ... 5
DCS1800: 1
...
2
DCS1900 1
...
2
State:
MSYN, MCE
Option:
none Query only
Note:
(N2)
Measured power of mobile (peak value)
SENSe:POWer:MS? is used to measure the transmitter power of the mobile.
SENSe:SIGNalling:POWer:LEVel? indicates the nominal value.
Syntax:
SENSe:POWer:MS?
Return:
RF In Out:
(0.0 + ext. att.) ... (+39 + ext. att.)
(unit: Dbm)
State:
MCE
Option:
none Query only (N7)
Frequency Band
Syntax:
SENSe:SIGNalling:FREQuency:BAND:CURRent?
SENSe:SIGNalling:FREQuency:BAND:SECOnd?
Return:
GSM850(arfcn:128-251)
P-GSM900 (arfcn: 0 - 124)
E-GSM900 (arfcn: 975 - 1023)
R-GSM900 (arfcn: 955-974)
GSM1800 (arfcn: 512 - 885)
GSM1900 (arfcn: 512 - 810)
Invalid - No frequency information on second network available (only
GSM900/GSM1800
mobiles provide frequency information).
Default:
DUM
State:
MSYN,
MCE
Option:
none
Query only
Note:
Current: Frequency information on current
network
Summary of Contents for 1094.0006.50
Page 4: ......
Page 12: ......
Page 22: ......
Page 24: ......
Page 26: ......
Page 28: ......
Page 30: ......
Page 41: ...CTS55 Getting Started With Autotest 1094 0006 55 3 3 E 7...
Page 66: ......
Page 81: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 7 E 6...
Page 83: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 9 E 6...
Page 106: ......
Page 108: ......
Page 196: ......
Page 246: ......
Page 250: ......
Page 254: ......
Page 256: ......
Page 343: ...CTS K6 Windows Application CTSgo 1079 2001 01 87 E 3 Fig CTSgo help window...