Publication 2094-UM001A-EN-P — September 2006
Connecting the Kinetix 6000 Drive System
91
Wiring the Input Power (IPD) Connector
This example applies to an integrated axis module (IAM) or leader
IAM (dc common bus).
Integrated Axis Module (IPD connector)
Input Power (IPD) Connections
Termination Specifications
DC-
DC+
L3
L2
L1
1 2 3 4 5 6
Integrated Axis Module, Top View
(2094-BC02-M02-S is shown)
OPL Connector (LIM) or Other Three-phase Input
IPD Connector
(IAM or leader IAM)
2094-AL09
2094-BL02, -AL
xx
S, -BL
xx
S,
or -XL75S-C
x
OPL Pin
Signal
OPL Pin
Signal
IPD Pin
Signal
1
L1’
4
L1’
6
L1
2
L2’
3
L2’
5
L2
3
L3’
2
L3’
4
L3
4
1
3
N/A
2
DC+
1
DC-
Integrated Axis Module
Cat. No.
Input VAC
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
Nm (lb-in)
2094-AC05-M
xx
-S
2094-AC09-M
xx
-S
230V ac
2.5 (14)
10 (0.38)
0.5 - 0.6
(4.4 - 5.3)
2094-AC16-M
xx
-S
10 (8)
16 (0.63)
2.4 - 3.0
(21.6 - 26.5)
2094-AC32-M
xx
-S
25 (4)
2094-BC01-M
xx
-S
2094-BC02-M
xx
-S
460V ac
4.0 (12)
10 (0.38)
1.2 - 1.5
(10.6 - 13.2)
2094-BC04-M
xx
-S
10 (8)
16 (0.63)
2.4 - 3.0
(21.6 - 26.5)
2094-BC07-M
xx
-S
25 (4)
Summary of Contents for Allen-Bradley Kinetix 6000
Page 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Page 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Page 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Page 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Page 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Page 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Page 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...