Publication 2094-UM001A-EN-P — September 2006
Upgrading Firmware
219
The Configure driver dialog opens.
6.
Enter the IP address of your Logix ethernet module.
The IP address shown is an example. Yours will be different.
7.
Click OK.
8.
Click Close in the Configure Drivers dialog.
9.
Select RSWho from the Communication menu.
The drive selection dialog opens.
10.
Locate your servo drive by expanding the ethernet node, Logix
backplane, and SERCOS interface module.
11.
Select the servo drive to flash.
12.
Click OK.
13.
Minimize the RSLinx application dialog and return to your
RSLogix 5000 project dialog.