Publication 2094-UM001A-EN-P — September 2006
Planning the Kinetix 6000 Drive System Installation
39
Resistive Brake Module
Noise Reduction Guidelines for Drive Accessories
When mounting an ac (EMC) line filter or external shunt resistor refer
to the sections below for guidelines designed to reduce system
failures caused by excessive electrical noise.
AC Line Filters
Observe the following guidelines when mounting your ac (EMC) line
filter (refer to the figure on page 36 for an example):
•
Mount the ac line filter on the same panel as the Kinetix 6000
drive and as close to the power rail as possible.
•
Good HF bonding to the panel is critical. For painted panels, refer
to the examples on page 28.
•
Segregate input and output wiring as far as possible.
Wire/Cable
Connections
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielded
Cable
Resistive brake module coil power
TB3-6 and TB3-7
X
Resistive brake module I/O
TB1-1...-5
and TB3-8
X
Resistive brake module
drive and motor power
TB1 and TB2
X
X
230V power
TB4
X
IMPORTANT
CE test certification applies only to ac line filter and single
power rail. Sharing a line filter with multiple power rails may
perform satisfactorily, but the user takes legal responsibility.
Summary of Contents for Allen-Bradley Kinetix 6000
Page 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Page 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Page 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Page 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Page 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Page 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Page 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...