Publication 2094-UM001A-EN-P — September 2006
158
Troubleshooting the Kinetix 6000 Drive System
MotFeedbackFault
(Mtr Fdbk AQB)
E20
Motor encoder has encountered an illegal state transition.
DISABLE
N
AuxFeedbackFault
(Aux Feedback Comm)
E21
Communication was not established with an intelligent (Stegmann)
encoder on the Auxiliary feedback port.
STOP
N
MotFeedbackFault
(Motor Feedback Comm)
E30
Communication was not established with an intelligent (Stegmann)
encoder on the Motor feedback port.
STOP
N
GroundShortFault
(Ground Fault)
E34
Excessive ground current in the converter was detected.
SHUTDOWN
N
DriveUndervoltageFault
(Precharge Fault)
E35
The converter pre-charge cycle has failed.
SHUTDOWN
N
DriveOvertempFault
(System Overtemperature)
E36
Converter internal temperature limit exceeded.
SHUTDOWN
N
PowerPhaseLossFault
(Phase Loss Flt)
E37
•
One or more phases of the input AC power is missing.
•
Axis was enabled when main (three-phase) power was removed.
•
Common bus follower axis was enabled when dc bus power was
removed.
SHUTDOWN/ STOP N
SERCOSFault
(SERCOS Ring Flt)
E38
The SERCOS ring is not active after being active and operational.
STOP
N
DriveHardFault
(Self Sense Flt)
E39
Self-sensing commutation fault detected.
DISABLE
N
DriveEnableInputFault
(Drive Enable Flt)
E43
Generated when Enable input switches off when drive is enabled.
STOP
Y
DriveHardFault
(Safe-Off HW Flt)
E49
Safe-off function mismatch. Drive will not allow motion. Refer to the
Kinetix Safe-off Feature Safety Reference Manual, publication
GMC-RM002, for more information. Applies to IAM
(2094-
x
C
xx
-M
xx
-S) and AM (2094-
x
M
xx
-S) with safe-off feature.
SHUTDOWN
N
SERCOSFault
(SERCOS Same ADDR)
E50
Duplicate node address detected on SERCOS ring.
STOP
N
DriveHardFault
(Ifbk HW Fault)
E54
Current feedback hardware fault detected.
SHUTDOWN
N
DriveHardFault
(Unknown Axis)
E60
Invalid module type identified by firmware when applying power.
SHUTDOWN
N
AuxFeedbackFault
(Aux Fdbk AQB)
E61
Auxiliary encoder has encountered an illegal state transition.
DISABLE
N
AuxFeedbackFault
(Aux Fdbk Loss)
E62
The feedback wiring is open, shorted or missing.
DISABLE
N
AuxFeedbackNoise
(Aux Fdbk Noise)
E63
Presence of noise on auxiliary feedback cable.
DISABLE
Y
MotorFeedbackNoise
(Mtr Fdbk Noise)
E64
Presence of noise on motor feedback cable.
No Fault Message
(condition indicated by
on-screen message)
(Hookup Fault)
E65
Hookup procedure failed.
DISABLE
N
Fault Message RSLogix
(HIM)
Error
Code
Description
Drive Fault
Action
RSLogix
Programmable
Fault Action?
Summary of Contents for Allen-Bradley Kinetix 6000
Page 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Page 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Page 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Page 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Page 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Page 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Page 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...