The disks belonging to the
replacement
node should show the new system ID. In the following example,
the disks owned by node1 now show the new system ID, 1873775277:
node1> storage disk show -ownership
Disk Aggregate Home Owner DR Home Home ID Owner ID DR Home ID
Reserver Pool
----- ------ ----- ------ -------- ------- ------- -------
--------- ---
1.0.0 aggr0_1 node1 node1 - 1873775277 1873775277 -
1873775277 Pool0
1.0.1 aggr0_1 node1 node1 1873775277 1873775277 -
1873775277 Pool0
.
.
.
Option 2: Manually reassign the system ID on systems in a two-node MetroCluster configuration
In a two-node MetroCluster configuration running ONTAP, you must manually reassign
disks to the new controller’s system ID before you return the system to normal operating
condition.
About this task
This procedure applies only to systems in a two-node MetroCluster configuration running ONTAP.
You must be sure to issue the commands in this procedure on the correct node:
• The
impaired
node is the node on which you are performing maintenance.
• The
replacement
node is the new node that replaced the impaired node as part of this procedure.
• The
healthy
node is the DR partner of the impaired node.
Steps
1. If you have not already done so, reboot the
replacement
node, interrupt the boot process by entering
Ctrl-C
, and then select the option to boot to Maintenance mode from the displayed menu.
You must enter
Y
when prompted to override the system ID due to a system ID mismatch.
2. View the old system IDs from the healthy node:
metrocluster node show -fields node-
systemid,dr-partner-systemid
In this example, the Node_B_1 is the old node, with the old system ID of 118073209:
1377
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...