If any volumes are listed in the output, NVE is configured and you need to verify the NVE configuration. If
no volumes are listed, check whether NSE is configured.
2. Verify whether NSE is configured:
storage encryption disk show
◦
If the command output list the drive details with Mode & Key ID information, NSE is configured and you
need to verify the NSE configuration.
◦
If no disks are shown, NSE is not configured.
◦
If NVE and NSE are not configured, it’s safe to shut down the impaired node.
Verify NVE configuration
1. Display the key IDs of the authentication keys that are stored on the key management servers:
security
key-manager query
◦
If the
Key Manager
type displays
external
and the
Restored
column displays
yes
, it’s safe to shut
down the impaired node.
◦
If the
Key Manager
type displays
onboard
and the
Restored
column displays
yes
, you need to
complete some additional steps.
◦
If the
Key Manager
type displays
external
and the
Restored
column displays anything other than
yes
, you need to complete some additional steps.
◦
If the
Key Manager
type displays
onboard
and the
Restored
column displays anything other than
yes
, you need to complete some additional steps.
2. If the
Key Manager
type displays
onboard
and the
Restored
column displays
yes
, manually backup
the OKM information:
a. Go to advanced privilege mode and enter
y
when prompted to continue:
set -priv advanced
b. Enter the command to display the key management information:
security key-manager onboard
show-backup
c. Copy the contents of the backup information to a separate file or your log file. You’ll need it in disaster
scenarios where you might need to manually recover OKM.
d. Return to admin mode:
set -priv admin
e. Shut down the impaired node.
3. If the
Key Manager
type displays
external
and the
Restored
column displays anything other than
yes
:
a. Restore the external key management authentication keys to all nodes in the cluster:
security key-
manager external restore
If the command fails, contact NetApp Support.
b. Verify that the
Restored
column equals
yes
for all authentication keys:
security key-manager
key query
c. Shut down the impaired node.
4. If the
Key Manager
type displays
onboard
and the
Restored
column displays anything other than
yes
:
a. Enter the onboard security key-manager sync command:
security key-manager onboard sync
7
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...