APPENDIX
App. - 16
App. 4.8 Technical data
App. 4.8.1 MR-J4 servo amplifier
(1) 200 V class
Item
MR-J4-10_/MR-J4-20_/MR-J4-40_/
MR-J4-60_/MR-J4-70_/MR-J4W2-22B/
MR-J4W2-44B/MR-J4W2-77B/
MR-J4W3-222B/MR-J4W3-444B
MR-J4-100_/MR-J4-200_/MR-J4-350_/
MR-J4-500_/MR-J4-700_/
MR-J4W2-1010B/MR-J4-11K_/
MR-J4-15K_/MR-J4-22K_
Main circuit (line voltage)
3-phase or 1-phase 200 V AC to 240 V AC,
50 Hz/60 Hz
3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
Control circuit (line
voltage)
1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
Power
Interface (SELV)
24 V DC, (required current capacity: MR-J4-_A, 500 mA; MR-J4-_B,
300 mA; MR-J4W2-_B, 350 mA; MR-J4W3-_B, 450 mA)
Control method
Sine-wave PWM control, current control method
Functional safety (STO)
IEC/EN 61800-5-2
EN ISO 13849-1 category 3 PL d, IEC 61508 SIL 2, EN 62061 SIL CL 2, and EN 61800-5-2 SIL 2
Mean time to dangerous failure
MTTFd
≥
100 [years]
Effectiveness of fault monitoring of
a system or subsystem
DC = 90 [%]
Average probability of dangerous
failures per hour
PFH = 1.68 × 10
-10
[1/h]
Mission time
TM = 20 [years]
Response performance
8 ms or less (STO input off
→
energy shut off)
Pollution degree
2 (IEC/EN 60664-1)
Overvoltage category
III (IEC/EN 60664-1)
Protection class
I (IEC/EN 61800-5-1)
Short-circuit current rating (SCCR)
100 kA
(2) 400 V class
Item
MR-J4-60_4/MR-J4-100_4/MR-J4-200_4/MR-J4-350_4/MR-J4-500_4/MR-J4-700_4/
MR-J4-11K_4/MR-J4-15K_4/MR-J4-22K_4
Main circuit (line voltage)
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Control circuit (line
voltage)
1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Power
supply
Interface (SELV)
24 V DC, (required current capacity: MR-J4-_A4, 500 mA; MR-J4-_B4, 300 mA)
Control method
Sine-wave PWM control, current control method
Safety function (STO)
IEC/EN 61800-5-2
EN ISO 13849-1 category 3 PL d, IEC 61508 SIL 2, EN 62061 SIL CL 2, and EN 61800-5-2 SIL 2
Mean time to dangerous failure
MTTFd
≥
100 [years]
Effectiveness of fault monitoring of
a system or subsystem
DC = 90 [%]
Average probability of dangerous
failures per hour
PFH = 1.68 × 10
-10
[1/h]
Mission time
TM = 20 [years]
Response performance
8 ms or less (STO input off
→
energy shut off)
Pollution degree
2 (IEC/EN 60664-1)
Overvoltage category
III (IEC/EN 60664-1)
Protection class
I (IEC/EN 61800-5-1)
Short-circuit current rating (SCCR)
100 kA
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......