12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 23
(3) At the time of alarm reset
If an alarm occurs, turn off SON by detecting ALM. If an alarm has occurred, ABSM cannot be accepted.
In the reset state, ABSM can be input.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
95 ms
OFF
ON
OFF
ON
SON
RES
ABSM
ABSR
ABST
ABSB0
ABSB1
Base circuit
ALM
RD
Occurrence of alarm
During transfer of ABS
Absolute position
data
Operation
enabled
OFF
ON