12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 17
12.6.2 Transfer method
The following shows a sequence how to turn on the base circuit while it is off state because SON is off, EM2
is off, or an alarm is occurring. In the absolute position detection system, every time SON is turned on,
ABSM should always be turned on to read the current position in the servo amplifier to the controller. The
servo amplifier transmits to the controller the current position latched when ABSM switches from off to on. At
the same time, this data is set as a position command value inside the servo amplifier. Unless ABSM (ABS
transfer mode) is turned on, the base circuit cannot be turned on.
(1) At power-on
(a) Timing chart
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
95 ms
95 ms
1)
2), 3)
Power
supply
SON
4)
ABSM
ABSR
ABST
Base circuit
RD
If SON is turned ON before ABSM is input
During transfer of ABS
During transfer of ABS
(Note)
(Note)
(Note)
(Note)
(Note)
(Note)
Absolute position
data
Operation
enabled
Operation
enabled
ABSB0
ABSB1
Absolute position
data
Note. For details, refer to (1) (b) of this section.
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......